Transformer Tank Fabrication for OEMs

Transformer Tanks

KREA manufactures welded steel tanks and structural assemblies for oil-immersed distribution and power transformers — plain and corrugated-wall tank bodies, conservators, radiators, cover plates and cable boxes — fabricated to customer drawings and the IEC 60076 series. We build the tank; the transformer OEM supplies the electrical active part.

Interactive 3D

Illustrative model — every part is built to your drawing.

Product Gallery

Explore our manufacturing excellence through real production images

Why Choose Our Products

Engineered for performance, built for durability

🔧

Custom-Engineered to Drawings

Every tank is fabricated to customer-supplied drawings and dimensional specifications rather than an off-the-shelf design

🧪

Full Tightness Testing

Positive pressure and/or vacuum leak testing performed on every tank before coating and dispatch

🎨

ISO 12944 Coating Systems

Shot blasted to Sa 2.5 and finished with primer and top-coat systems matched to the specified corrosivity category

🏗️

EN 1090 Structural Fabrication

Structural steelwork and heavy tank assemblies welded under EN ISO 3834-2 quality requirements and EN 1090 execution class EXC3 where specified

Product Variants

Choose from our range of solutions

Distribution Transformer Tanks (Corrugated-Wall)

Corrugated steel-wall tank bodies for oil-immersed distribution transformers. The corrugated fin surface acts as the primary cooling area, removing the need for separate radiator banks on smaller units.

Capacity Range: 300 - 5,000 liters

Key Features

  • Corrugated wall panels as integral cooling surface
  • Pressure relief valve and Buchholz relay mounting provisions
  • Lifting lugs and jacking pads
  • Conservator and cover mounting flanges

Applications

Distribution transformersPole and pad-mounted transformersMV/LV substationsUtility distribution networks

Technical Specifications

Plate Thickness
2mm - 4mm (corrugated wall), 6mm - 12mm (cover/base)
Capacity Range
300 - 5,000 liters
Material
S235JR / S355JR structural steel plate
Welding
EN ISO 3834-2 qualified robotic & manual MIG/MAG welding
Testing
Positive pressure / vacuum tightness testing per customer specification
Coating
Shot blasted Sa 2.5, primer + finish coat per ISO 12944
Standards
Built to IEC 60076 series and customer drawings

Power Transformer Tanks (Plain-Wall, Stiffened)

Heavy plain-wall tanks with welded stiffening ribs for large power transformers, engineered for structural rigidity under vacuum, oil load and transport stresses.

Capacity Range: 5,000 - 100,000+ liters

Key Features

  • Stiffened plain-wall construction to customer structural design
  • Bushing turret and cable box mounting provisions
  • Jacking lugs, skid base and wheel/undercarriage options
  • EN 1090 EXC3 structural fabrication

Applications

Power transformersSubstation transformersGenerator step-up transformersIndustrial power transformers

Technical Specifications

Plate Thickness
6mm - 30mm
Capacity Range
5,000 - 100,000+ liters (per drawing)
Material
S235JR / S355JR structural steel plate
Welding
EN ISO 3834-2 qualified welding, EN 1090 EXC3 structural fabrication
Testing
Vacuum & pressure tightness testing per customer specification
Coating
Shot blasted Sa 2.5, coating system per ISO 12944 corrosivity category (as specified)
Standards
Built to IEC 60076 series and EN 1090 to customer drawings

Conservators, Radiators & Accessory Weldments

Conservator tanks, detachable radiator/cooling-fin banks, cover plates, bushing turrets and cable boxes fabricated as accessory weldments to complete the transformer tank assembly.

Size Range: 50 - 2,000 liters (conservators)

Key Features

  • Conservator tanks with oil-level gauge mounting
  • Detachable radiator cooling banks
  • Cover plates, bushing turrets and terminal enclosures
  • Expansion, breather and drain valve connections

Applications

Conservator systemsRadiator cooling banksCover and turret assembliesCable box enclosures

Technical Specifications

Plate Thickness
2mm - 8mm
Capacity Range
50 - 2,000 liters (conservators); custom radiator bank sizes
Material
S235JR / S355JR structural steel plate, stainless steel where specified
Welding
EN ISO 3834-2 qualified welding
Testing
Leak / tightness testing per customer specification
Coating
Shot blasted Sa 2.5, primer + finish coat per ISO 12944
Standards
Built to IEC 60076 series and customer drawings

Quality Certifications

Our products meet the highest international standards

ISO 9001:2015
EN ISO 3834-2
EN 1090 EXC3
ISO 12944
Sa 2.5 Shot Blasting
IEC 60076 (customer specification)

Frequently Asked Questions

What is included in KREA's transformer tank manufacturing scope?

KREA manufactures the welded steel tank body and structural steel assemblies for oil-immersed transformers — plain and corrugated-wall tanks, conservators, radiators, cover plates, bushing turrets, cable boxes and skid bases — built to customer drawings and the IEC 60076 series. KREA does not manufacture the electrical active part (core and windings) or supply a complete finished transformer; tanks are supplied to transformer OEMs who insulate, fill and commission the unit.

What steel grades and plate thicknesses do you use for transformer tanks?

Tanks are fabricated from S235JR and S355JR structural steel plate in thicknesses from 2mm for corrugated-wall panels up to 30mm for heavy power transformer tank walls and covers, selected according to your structural design and the IEC 60076 series.

Do you test transformer tanks for oil-tightness?

Yes. Every tank undergoes leak and tightness testing — positive pressure and/or vacuum testing as specified by the customer — before shot blasting and coating, with test records included in the quality documentation package.

What coating system do you apply to transformer tanks?

Tanks are shot blasted to Sa 2.5 cleanliness and finished with a primer plus top-coat paint system selected to the ISO 12944 corrosivity category specified by the customer, suitable for outdoor substation and utility service environments.

Can you weld and fabricate transformer tanks to our own drawings and specifications?

Yes, we build strictly to customer-supplied drawings and specifications, including plate thickness, stiffening layout, bushing and cable box placement, lifting and jacking provisions and coating system, with welding carried out under EN ISO 3834-2 quality requirements and structural fabrication to EN 1090 EXC3 where specified.

Ready to Discuss Your Project?

Our engineering team is ready to design the perfect solution for your application